NO. | Classification | Name | Specification |
1 | StandardDimension/specification | Length: | Designing according to requirement, normally not more than 60m |
2 | Width: | Should be no more than 13m | |
3 | Eavesheight: | Not more than 4.5m | |
4 | RoofGradient | 11°,1:5 | |
5 | Columnspan | Less than 4m | |
6 | Purlin span | Less than 1.5m | |
7 | Column | C profile steel, as per building span, metal code Q345. | |
8 | Roof beam | C profile steel, as per building span, metal code Q345. | |
9 | Wall panel | Rock wool sandwich panel, designing accordingto requirement,recommend thickness: 50mm,75mm,100mm,150mm | |
10 | Roofpanel | Rock wool corrugated panel, designing according to requirement,recommend thickness: 50mm, 75mm,100mm,150mm | |
11 | Door | Metal door,size:840mm*2035mm | |
12 | Window | PVC slidingwindow | |
1 | Option | Door | Size and material can be made accordingto requirement, securitydoor,wooden door, aluminum door, PVC door, glass door etc. |
2 | Window | Size and material can be made according to requirement | |
3 | Ceiling | Standard Water-proof gypsum boardOption: silicate calciumtile, mineral wool board, aluminum buckleplate,PVC tile | |
4 | Plumbingsystem | Supply planning, designing and technical service | |
5 | Electricalsystem | Supply planning, designing andtechnical service | |
1 | Structure | Roofloading | 0.5KN/㎡(standard), can be customized |
2 | Windresistance | 0.45KN/㎡ | |
3 | Earthquake-resistance | 7 degrees |
Profile | 1 | Length | Normally not more than 60m |
2 | Width | ≤13000mm | |
3 | Height | Eave height of single storey less than 4500mm, two storey less than 7000mm | |
4 | Roof Type | Gable roof, slope 1:5; flat roof, slope 1:20 | |
5 | Storey | 1-2 storey | |
Parameter | 6 | Roof Dead Load | 0.3KN/㎡ |
7 | Floor Deal Load | 0.5KN/㎡(standard), can be customized | |
8 | Floor Live Load | 2.0KN/㎡ | |
9 | Roof Live Load (Snow Load) | 0.5KN/㎡ | |
10 | Wind Load | 0.45KN/㎡ | |
Frame | 11 | Column | C profile steel, as per building span, metal code Q345. |
12 | Roof Beam | C profile steel, as per building span, metal code Q345 | |
13 | Multi-floor Beam | C profile steel, as per building span, metal code Q345 | |
14 | Purlin | C85*40*11*1.8 profile steel, metal code Q235/ C120*60*15*1.5 profile steel, metal code Q345 *can be customized as per building layout | |
15 | Anti-corrosion Treatment | All frame adopts hot dip galvanization, mass of Zn coating 80g/m²;the joint plate adopt anti-corrosion painting. The treatment of galvanization and painting can be decided as per climate condition and customers' requirement. | |
Roof | 16 | Material | 50mm - 150mm sandwich panel. The metal sheet can be 0.35-0.5mm in thickness |
17 | Color steel metal sheet can be used as per the building function. The metal sheet should be not less than 0.5mm in thickness. | ||
18 | Glass wool, the density is not less than 50Kg/m³, Fire-proof in Class A. | ||
Wall | 19 | Material | 50mm - 150mm sandwich panel. The metal sheet can be 0.35-0.5mm in thickness |
20 | Color steel metal sheet can be used as per the building function. The metal sheet should be not less than 0.5mm in thickness. | ||
21 | Glass wool, the density is not less than 50Kg/m³, Fire-proof in Class A. | ||
Door | 22 | Size | 840*2035 |
23 | Material | Metal door | |
Window | 24 | Size | 1125*1490/500*500 |
25 | Type | Sliding window, top swing window | |
26 | Frame | Standard:PVC | |
27 | Glass | Standard: single glazed 4mm glassOption: double glazed 5mm glass | |
Ceiling | 28 | Material | Standard: Water-proof gypsum boardOption: silicate calcium tile, mineral wool board, aluminum buckle plate, PVC tile *decided by room condition and local climate conditions |
Floor | 29 | Suspended Flooring System(500mm high in standard) | Integrated bathroom should be used for toilet. Dry room uses laminated wood flooring plate or PVC flooring sheet |
30 | Common Floor | (Single storey)wet room uses anti-slipping tiles and dry room uses common ceramic tiles | |
Multi-flooring | 31 | Dry Room | Laminated wood flooring plate |
32 | Wet Room | Integrated bathroom | |
Electrics | 33 | Capable to provide engineering, layout and construction services | |
34 | Lamp | LED 8W/13W/16W for selection *as per room area and room functions | |
35 | Socket | Three-pole multi-functional socket(250V 16A) | |
36 | Electric Wires | For lamp BV-1.5mm² /common socket BV-2.5mm² /AC and water heater socket BV-4mm² | |
37 | Voltage | 220/380V | |
38 | Breakers | high breaking circuit breaker/leakage protection circuit breaker *as per functions | |
Plumping | 39 | Capable to provide engineering, layout and construction services | |
40 | Water Supply | PPR | |
41 | Water Drainage | UPVC |